Quality Standards
We are quality conscious and adhere to a standard quality management policy supported by a dedicated quality control unit. We monitor the quality of incoming raw material as per Standards and carry out Quality Control during various stages of manufacturing. Finished goods are dispatched only after quality checking and all quality records are systematically maintained.
The quality standards maintained by us are as under :--
ATTRIBUTE |
ACCEPTANCE LIMITS |
THICKNESS |
+/- 0.02mm |
LENGTH |
Upto 700mm + 0.0/ - 0.5mm |
701 to 2000mm + 0.0 / -1.0mm |
|
Over 2000 mm + 0.0 / - 1.5 mm |
|
WIDTH |
Upto 150 mm +/- 0.1 mm |
151 to 500 mm +/- 0.2 mm |
|
501 mm and above +/- 0.3 mm |
|
CAMBER |
1.0 mm max. on 2000mm length |
V NOTCH |
90 deg +/- 5 minutes |
MITRED ANGLE |
45 deg +/- 5 minutes |
HOLE DIAMETER |
+ 0.10 / - 00mm |
STACKING FACTOR |
95.0% min. for 0.23mm thick material |
96% min. for 0.27mm and 0.30mm thick material |
|
97% min. for 0.35mm thick material |
|
INSULATION RESISTANCE |
Min. 10 Ohms/cm2 as per Franklin method described in IS 649-1996 |
BURR |
25 microns maximum |
WEIGHT OF EACH STEP |
+ 0.5% to 1.0% or as per customer's requirements. |
WATT LOSS |
M3 Grade: Max .77 watts/kg at 1.5T and 50Hz |
M4 Grade: Max 0.89 watts/kg at 1.5T and 50Hz |
|
M5 Grade : Max 0.97 watts/kg at 1.5T and 50 Hz. |
|
M6 Grade: Max 1.1 watts/kg at 1.5T and 50 Hz |